Request a quoteRequest a quote
Contact Contact

neurocare SAM

Mobile Bluetooth neurofeedback system with standardized neurofeedback protocols for frequency band and SCP training

Clinical experience and mechanisms

In our neurocare clinics, neurofeedback is primarily used to treat ADHD and sleep disorders with “standard” protocols (SMR, SCP, theta/beta). Based on clinical experience and initial empirical findings, tinnitus (Jensen M. et al., 2023), autism (Klöbl M. et al., 2023) and trauma (Dr. Edith Schneider, Stuttgart) may prove to be further areas of application.

Learning and effect mechanisms can differ between the various neurofeedback protocols. While SMR neurofeedback targets sleep-associated patterns in the EEG and is typically used more as a conditioning approach, SCP neurofeedback could be a tool to improve self-regulation skills on a cognitive, emotional and behavioral level by strengthening fronto-striatal networks.

In contrast to other exogenous neuromodulatory approaches that stimulate the brain (e.g. TMS, tDCS), neurofeedback is an endogenous approach. In the long term, the combination of different approaches can facilitate successful treatment.

neurocare SAM System
neurocare SAM System: Vollausstattung
neurocare SAM Verstärker
innovativer neurocare SAM Bluetooth-Verstärker
neurocare SAM aktive Elektroden
innovativer neurocare SAM Verstärker mit angeschlossenen aktiven Elektroden
neurocare SAM_Sams adventure
neurocare SAM Software: Sams Abenteuer
neurocare SAM_minigames
neurocare SAM-Software: Minispiele für SCP, SMR, Theta/Beta
neurocare SAM_Analyse SCP
neurocare SAM-Software: Analyse einer SCP-Sitzung
neurocare SAM Verstärker in Hand
neurocare SAM Verstärker: klein, handlich, innovativ

neurocare SAM - the software

neurocare SAM transforms therapy into an enganging, visually guided journey, led by a friendly companion named SAM who supports patients throughout the sessions. This strengthens their emotional connection to the therapy and boosts motivation to stay committed.

The software is based on standardized protocols (SCP, Theta/Beta, SMR) and supports you with automated analyses and flexible session planning.

Bildschirm mit SCP-Training

neurocare SAM - the ampifier

Our latest generation of neurofeedback is a lightweight with powerful functionality. Meassuring just 8 cm in diameger - about the size a jar of cream - the amplifier is compact and can be comfortably worn on the body using a strap or clip.
With the the active electrodes, which pre-amplify the signals and thus significantly reduce interference and artifacts, neurocare SAM provides highly precise measurements of slow cortical potentials (SCP) and frequency bands.
The amplifier transmits the measurement data to the computer wirelessly via Bluetooth.

neurocare SAM_Verstärker-rendering

Configurations

neurocare SAM - system

neurocare SAM software, neurocare SAM amplifier, active electrodes, computer, 2 monitors, mouse, keyboard

neurocare SAM amplifier and neurocare SAM software

neurocare SAM software and amplifier with active electrodes for your own computer system

Configuration: neurocare SAM system

This setup offers you the highest level of safety and comfort. 

You receive a tested and approved system from us, consisting of the neurocare SAM software package and the innovative neurocare SAM amplifier, along with two 23.8" screens with integrated computer, mouse and keyboard. All components are seemlessly integrated and get you up and running in just a few minutes.

neurocare SAM System_1

Configuration for your own computer

Are you already equipped with siutable IT infrastructure and would like to use it for neurofeedback? No problem. This configuration includes the innovative neurocare SAM amplifier and the neurocare SAM software package delivered on a USB stick. You provide the computer system that works best for you and set up neurocare SAM on your computer independently.

Please ensure that your computer or laptop meets the technical requirements before installation.

neurocare SAM_collage_Verstärker-Software

Technical features

  • neurocare SAM amplifier, active electrodes

    The advantages of the neurocare SAM amplifier at a glance:
    • very easy handling
    • excellent signal quality
    • small and light, can be worn on the body
    • wireless transmission of measurement data to the computer via Bluetooth
    • battery life of more than one working day

    Technical data:

    • 8 full-band DC channels for feedback of slow cortical potentials (SCP), SMR and of frequency bands
    • Sampling rate: 500 sps
    • Frequency range 0 Hz to 120 Hz at sampling rate 500 sps
    • Power supply via built-in lithium-ion polymer battery; inductive charging of the battery via a charging cradle
    • Data transmission to the PC via Bluetooth Low Energy (5.0)
    • Continuous operating time > 12 h
    • Dimensions: Diameter: 80 mm,
    • Height: 20 mm
    • Weight: just over 100 g
  • neurocare SAM software

    Intuitive user interface: structured software with logical workflow

    • quick access to patient file, therapy history, protocols, progress charts
      Easy selection of protocols: slow cortical potentials (SCP), SMR, theta/beta

    Automated evaluation & documentation:

    • real-time analysis and feedback of EEG data
    • automatic creation of progression curves, session analyses, etc.
    • data protection compliant (DSGVO)

    Clear progression planning and target definition:

    • The accompanying story based on the adventures of the avatar SAM sets intermediate goals and motivates.
  • Computer system - only relevant for complete system

    Wortmann TERRA LCD/LED, 2465 W, PV white, with USB-C / DP / HDMI GREENLIGHT

    • height-adjustable TERRA All-In-One PC in the new stylish, completely white, frameless design
    • the powerful Intel Core i5 CPU is elegant, performant and quiet

    Technical data 
    General
    • processor: Intel Core i5 (12th Gen.) 12400 / 2.5 GHz up to 4.4 GHz with Intel Turbo Boost Technology, 18 MB Intel Smart Cache
    Software
    • operating system: Windows 11 Pro
    • pre-installed software: 1 month trial version for new Microsoft® 365 customers
    Display
    • display resolution: 1920 x 1080 ( Full HD )
    • display type: Non-touch LCD display
    • brightness: 250 cd/m²
    • response time: 14 ms
    • contrast ratio: 1300:1
    • horizontal viewing angle: 178°
    • vertical viewing angle: 178°
    • LED backlight type: LBL (Hardware Low Bluelight) 
    • screen diagonal: 60.5 cm (23.8")
    Hard disk
    • total storage capacity: 500 GB
    Dimensions
    • height: max.: 52.0 min.: 38.9 cm
    • width: 54.0 cm
    • depth: 5.4
    • footprint: 25.4 x 24.3 (W x D) cm
    • weight: 7.5 kg
  • You use your own computer - that is what you provide

    Would you like to use the neurocare SAM amplifier and the software with your own computer? Please make sure that the following requirements are met:

    • Minimum requirements for your computer / laptop: Intel CPU, min. 1.6 GHz, min. 1 GB RAM, min. 250 GB hard disk
    • We recommend the use of 2 screens - one for the therapist, one for the patient. You will need graphics cards with a minimum resolution of 1024 x 768 pixels and at least 24-bit color depth.
    • Resolution for the therapist screen: 1536 x 1024
    • Resolution for the patient screen: 1024 x 768
    • Stereo sound card plus speakers
      Laptops should be plugged in and running at least in high-performance mode.
    • Bluetooth 5.0 is required for use with the neurocare SAM amplifier.
    • For use with PET amplifier: Bluetooth interface
    • Operating system: Windows 10 Professional (and higher)

Neurofeedback - the methode

booklet:
Neurofeedback

booklet:
Applications of tDCS

Enquire today

We are here to help you find the right technology and training for your practice or research

Learn more about our best practice platform and clinics

Subscribe to Newsletter