DuoMAG XT for TMS in clinical application

The DuoMAG XT is a compact bi-phasic stimulator for both clinical and research use. The stimulator is controlled via a large capacitive touch-screen Windows based interface, allowing for ease of use and elaborate protocol setup and configuration. A full selection of coils are available depending on application. Intensity and stimulation controls are included on all deymed coils.

  • The Deymed DuoMag system is unique with it’s lockable coil positioning system, that locks the coil in a fixed position and can be operated easily with one hand by its counterbalanced coil holder.

  • For regulare clinical use including slow rTMS (1 Hz) or fast rTMS (e.g. 10 Hz) the XT-35 is the perfect system.

  • For more research applications or the need for advanced stimulation options such as Theta-burst stimulation, the XT-100 is the best choice.

DuoMAG XT Features

  • System control and configuration via Windows based touch-screen.
  • Controllable from an external device.
  • Custom protocol editor and storage by way of built-in computer.
  • Burst function fully configurable (iTBS, cTBS etc).
  • Supported by a complete range of Circular, Figure 8 and Cooled Coils.
  • Custom protocol editor allowing saving of any conceivable design, including stimulation trains, Theta Burst Stimulation (iTBS-cTBS) and changing stimulation intensities.
  • FlexiTower cart: innovative counter-weight balanced positioning arm and auto-locking of position that greatly reduces the effort needed to find and fix the placement of Deymed coils.
  • Integration of Deymed's clinical EMG or EEG amplifiers, allowing multiple configuration of EMG/MEP or EEG signals to be displayed.


Specifications
Product Specifications DuoMAG XT-35 DuoMAG XT-100
Pulse mode biphasic, repetitive biphasic, repetitive, burst
Dimensions 49 cm x 11 cm x 38 cm 49 cm x 11 cm x 38 cm
Weight without trolly and coil 15 kg 16 kg
Stimulation Intensity 100% 12 Hz 15 Hz
Stimulation Intesity 50% 35 Hz 80 Hz
Maximum repetition rate 35 Hz 100 Hz
Minimum interstimulus interval
in train mode
1ms 1ms
Pulse width 280 µs 280 µs
Coil Compatibility Deymed coils Deymed coils
Main voltage 100-240 Vac. 50/60 Hz 100-240 Vac. 50/60 Hz
Synchronization TTL in/out and/or USB TTL in/out and/or USB
Communication USB full control, control on coil USB full control, control on coil

A motor threshold (MT) can be found at 47% stimulation intensity for the majority of the population (>90%) on all devices.


DuoMAG XT - kompatible Systeme und Geräte


Produktinformationen zum Download

Weitere Detail und technische Daten zum DuoMAG XT finden Sie in der Produktbroschüre.

DuoMAG XT Broschüre
Download PDF


neuroCademy-Kurse zur therapeutischen Anwendung der rTMS

neuroCademy bietet mehrmals im Jahr 2-tägige Workshops zur rTMS bei der Behandlung von Depressionen und Zwangsstörungen im klinischen und wissenschaftlichen Umfeld an. Der Kurs erklärt darüber hinaus, wie EEG und QEEG eingesetzt werden können, um den Behandlungserfolg abzuschätzen und zu optimieren. Die Teilnehmer üben die Anwendung an verschiedenen rTMS-Geräten.

Unser Workshop "Advanced Neurostimulation Techniques" vermittelt Forschern, Ärzten und Psychologen detaillierte Informationen über unsere Lösungen für die transkranielle Hirnstimulation sowie deren Kombination mit Neuroimaging-Verfahren. Unter Anleitung unserer erfahrenen Spezialisten üben Sie die verschiedenen Anwendungen zur mehrkanaligen tES, zur TMS-Navigation und zur Kombination von nicht-invasiven Hirnstimulationsverfahren mit EEG-Technologie.

Detaillierte Informationen und Kurstermine der neuroCademy-Workshops >